Water Treatment Machine Ro water Treatment Plant
How the Reverse Osmosis Works
The ro water treatment is a process in which dissolved inorganic solids (such as salts) are removed from a solution (such as water). This is accomplished by pressure of high pressure pump pushing the water through a semi permeable membrane. The membrane (which is about as thick as cellophane) allows only the water to pass through, not the impurities or contaminates. These impurities and contaminates are flushed down the drain.
Ultimately, the factors that affect the performance of a Reverse Osmosis System are:
Incoming water pressure
Water Temperature
Type and number of total dissolved solids (TDS) in the water
The quality of the filters and membranes used in the RO System (see operating specs)
How to Select the Right Water Treatment Machine Ro water Treatment Plant
Crane Environmental has the most complete line of Reverse Osmosis equipment in the industry. To select the right Reverse Osmosis system for your application, there are four primary considerations; the type of raw water, the quality of the product water required, the capacity of product water required, and any special features such as storage, repressurization, or mounting.
Technical route and flow diagram instructions
The technical route is as following.
Raw tank-->Booster pump -->Quartz sand filter-->activated carbon filter--->Anti-scalant
dosing-->Sediment filter-->High pressure pump-->RO desalination device-->Permeate tank
Water Treatment Machine Ro water Treatment Plant Features
Materials of Construction
Skid Frame: SS304
Membrane Elements:Hydranautics CAP3-8040
Membrane Housings: SS304
Low pressure piping: SS304
High pressure piping: SS304
Pump and Motor
Pump: 304SS vertical multi-stage centrifugal
Motor: TEFC, 380/460 VAC, 3-phase, 50/60 Hz.
Standard Features
8" x 40" High rejection membrane elements
5-micron sediment pre-filter housing
Automatic inlet solenoid valve
PLC control
Product water conductivity monitor
Operating pressure gauges
Product and concentrate flow meters
Concentrate and recycle flow control valves
Low inlet pressure switch with shutdown alarm
Auto/Manual wash
Optional Equipment Available
Atmospheric storage tanks with level control and repressurization pump
Pressurized storage vessels
UV
Ozone generator
Membrane clean-in-place (CIP) systems
Pretreatment chemical injection systems
Water Treatment System Specification :
Model No | WT-RO-5000 |
Capacity | 5000LPH(Liter per Hour) |
Nominal Recovery | 65-75% |
Nominal Salt Rejection | 99.60% |
Operating Temperature | 15°C-45°C |
Design Temperature | 25°C |
Feed Pump | 1.10KW |
High Pressure Pump | 5.50KW |
Voltage | 220V /380V/460V - 50Hz/60Hz |